ETN YE-K 65/26-2-30 - 10-7 (70m³/h-70mSS) 2Electric+1Jokey TS EN 12845 Fire Pump Set

16.260,16 USD
Category
Brand
Stock code
etnye70702e1j
Manufacturing Period
24 Month
Price
16.260,16 USD


ETN YE-K 65/26-2-37-10-7 FIRE PUMP SET IN ACCORDANCE WITH TS EN 12845+A2 NORMAL
(70m³/h - 70mSS) - 2 ELECTRIC + 1 JOCKEY PUMP

FIRE PUMP IN ACCORDANCE WITH TS EN 12845+A2 NORMAL
Suitable for use in fire installations containing sprinklers,
They are fire pump systems consisting of chassis type end suction pumps.
You can contact us for the product that suits your project values.


ABOUT TS EN STANDARD

TS EN 12845+A2 Standard; It is the same as EN 12845+A2 Standard and is the "Turkish Fire Standard" created by Turkish Standards Institute with the permission of European Committee for Standardization (CEN). In the process of creating this standard; EN 12845+A2 standard accepted by CEN was taken as basis and prepared by TSE Engineering Services Specialization Group and it was accepted as "Turkish Standard" and decided to be published in the meeting of TSE Technical Board on July 19, 2012.
 
Why Should a Fire Pump Compliant with TS EN 12845+A2 Be Used?

According to the provisions of the "Regulation on the Protection of Buildings from Fire" and the TS EN 12845+A2 fire pump standard in force; precautions to be taken against fire and the "fire pump" to be installed must be in accordance with the provisions of the regulation. If there is a situation that does not comply with the provisions of the regulation, the building will not be given an occupancy permit (use permit). Due to fire damages that may occur due to non-compliance with the provisions of the regulation; the employer, employer representatives, architects and engineers responsible for design and implementation, building inspection organizations, contractors, manufacturers and consultants are jointly and severally liable according to their faults. Systems containing sprinklers must be designed in accordance with TS EN 12845+A2 and the fire pump to be used must be in accordance with TS EN 12845+A2, which is the fire standard of Turkey.


SCOPE OF DELIVERY

EXPLANATION
Flow
(m³/h)
Pressure
mSS
PRODUCT TYPE
Strength
kW
Transfer
rpm
Wheel
Diameter
Suction
Diameter
Print
Diameter
Amount
Piece  
FIRE HYDROPHORE GROUP - (2Electric +1jockey)
COMPLIES WITH TS EN 12845 NORMAL
ETN YE-K 65/26-2-30 - 10-7 1
Electric Main Pump 70 70 EA 65/26 30 2900 226 Ø Pump Suction Diameter DN80 DN150 Press Handle. 1
Electric Backup Pump 70 70 EA 65/26 30 2900 226 Ø 1
Jockey Pump 5 75 KO 10/7-30 3 2900 1
Hydrophore Tank + Flex
100LT PN16 1
Main-Spare-Jockey Pump Control Panel (Separate for each pump)
Delivery collector, Delivery line Butterfly valve, Pressure reduction, check valve, pressure switch, manometer,
SUCTION KIT GROUP-Eccentric suction kit (DN80xDN125), Butterfly valves (DN125) for each pump
Our hydrophore is shipped as a common chassis. Assembly is not included.
Our offer is prepared assuming that there is no negative suction. If there will be negative suction, please contact us.


WARNING

In order for the product to be under warranty, it must be commissioned by ETNA Authorized Services.
The commissioning process is done free of charge.
The product is produced to order and the estimated delivery time is 14 business days.

TECHNICAL BROCHURE


ASSEMBLY VIDEO


Be the first to review this product!
Price information, pictures, product descriptions and other issues that you find inadequate points you can send us using the suggestion form.
Thank you for your comments and suggestions.
ETN YE-K 65/26-2-30 - 10-7 (70m³/h-70mSS) 2Electric+1Jokey TS EN 12845 Fire Pump Set etnye70702e1j
ETN YE-K 65/26-2-30 - 10-7 (70m³/h-70mSS) 2Electric+1Jokey TS EN 12845 Fire Pump Set

Recommend

*
*
*
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.